or to view stock quantity and your pricing.
Steiner serves territories in Northern Illinois, Northwest Indiana and Southern Wisconsin. Please for assistance if outside our sales territory.
Schneider Electric NSYCVF165M48DPF NSY Fan, 25 to 55.2 V, 0.18 A, 8.7 W power rating, 50986.12 gph air flow, IP54 enclosure
Schneider Electric NSYCVF165M48DPF NSY Fan, 25 to 55.2 V, 0.18 A, 8.7 W power rating, 50986.12 gph air flow, IP54 enclosure
SKUPDW~13599739
MFGR #NSYCVF165M48DPF
Call For Price
List: Schneider Electric NSYCVF165M48DPF, Fan, NSY, 25 to 55.2 V, 0.18 A, 8.7 W Power, 50986.12 gph Air Flow, IP54 Enclosure, 10.55 in H x 9.76 in W x 4.09 in D Dimensions
Schneider Electric NSYCVF165M48DPF, Fan, NSY, 25 to 55.2 V, 0.18 A, 8.7 W Power, 50986.12 gph Air Flow, IP54 Enclosure, 10.55 in H x 9.76 in W x 4.09 in D Dimensions
Alternate Catalog Number NSYCVF165M48DPF Application For ced ClimaSys forced vent, For ced vent, For ced ARRA Compliant N Buy American Compliant N Catalog Number NSYCVF165M48DPF Color Outlet grille Gray RAL 7035) Country of Origin FR Currency USD Depth External 104 mm in EU RoHS Indicator Y Gross Volume Per Pack 61.02 Gross Volume per Pack Metric 1000.00 Gross Volume UOM CI Gross Volume UOM Metric cm3 Gross Weight Per Pack 0.0105 lb Gross Weight per Pack Metric 1.05 Gross Weight UOM Metric kg Harmonization Tariff Schedule Code 8414596590 Height 18.5000 in Height [Metric] 18.0000 cm Length 27.0000 in Length [Metric] 25.5000 cm Material Outlet grille injected thermoplastic (ASA PC) Material Composition Declaration https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=export&pid=10178370&lang=en-us Returnable N UNSPSC 39121324 Warranty Description Contractual Warranty:18 months Width 25.5000 in Width [Metric] 18.5000 cm Brand Square D™ Manufacturer Schneider Electric For ced ClimaSys forced vent, For ced vent, For ced The ambient temperature is lower than the desired temperature inside the enclosure A high protection rating is required: IP 54 or IP 55 The surrounding environment is relatively clean, allowing air to enter the enclosure 42 possible combinations Colours: RAL 7035 as standard, with the option of changing to RAL 7032 (with replacement grille NSYCAG***LPC 38 to 850 m3/h According to 5 input voltages:AC: 400/440 V, 230 V, 115 V (50/60 Hz),DC: 48 V and 24 V Broad range of accessories (filters, IP 55 & EMC covers, anti-vandalism kit) Standard type of filter 48 V DC input voltage 48 V DC input voltage 8.7 W absorbed power 50 to 51 dB noise level < at Ball bearing type 223 x 223 mm cut-out dimensions 50 Pa flow rate 0 m3/h maximum pressure Surrounding environment must be relatively cleanOutside temperature must be 5 deg C lower than inside temperatureOverfrequent filter replacement should be avoidedFilter must be cleaned and replaced regularlyFlow rates depends on the work point, see ProClima software condition of use
content loaded
content loaded
content loaded
content loaded
content loaded
- Attributes
- Documents & Resources
- Applications
- Features
- Substitute Products
| Alternate Catalog Number | NSYCVF165M48DPF |
| Application | For ced ClimaSys forced vent, For ced vent, For ced |
| ARRA Compliant | N |
| Buy American Compliant | N |
| Catalog Number | NSYCVF165M48DPF |
| Color | Outlet grille Gray RAL 7035) |
| Country of Origin | FR |
| Currency | USD |
| Depth | External 104 mm in |
| EU RoHS Indicator | Y |
| Gross Volume Per Pack | 61.02 |
| Gross Volume per Pack Metric | 1000.00 |
| Gross Volume UOM | CI |
| Gross Volume UOM Metric | cm3 |
| Gross Weight Per Pack | 0.0105 lb |
| Gross Weight per Pack Metric | 1.05 |
| Gross Weight UOM Metric | kg |
| Harmonization Tariff Schedule Code | 8414596590 |
| Height | 18.5000 in |
| Height [Metric] | 18.0000 cm |
| Length | 27.0000 in |
| Length [Metric] | 25.5000 cm |
| Material | Outlet grille injected thermoplastic (ASA PC) |
| Material Composition Declaration | https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=export&pid=10178370&lang=en-us |
| Returnable | N |
| UNSPSC | 39121324 |
| Warranty Description | Contractual Warranty:18 months |
| Width | 25.5000 in |
| Width [Metric] | 18.5000 cm |
| Brand | Square D™ |
| Manufacturer | Schneider Electric |
| For ced ClimaSys forced vent, For ced vent, For ced |
| The ambient temperature is lower than the desired temperature inside the enclosure |
| A high protection rating is required: IP 54 or IP 55 |
| The surrounding environment is relatively clean, allowing air to enter the enclosure |
| 42 possible combinations |
| Colours: RAL 7035 as standard, with the option of changing to RAL 7032 (with replacement grille NSYCAG***LPC |
| 38 to 850 m3/h |
| According to 5 input voltages:AC: 400/440 V, 230 V, 115 V (50/60 Hz),DC: 48 V and 24 V |
| Broad range of accessories (filters, IP 55 & EMC covers, anti-vandalism kit) |
| Standard type of filter |
| 48 V DC input voltage |
| 48 V DC input voltage |
| 8.7 W absorbed power |
| 50 to 51 dB noise level < at |
| Ball bearing type |
| 223 x 223 mm cut-out dimensions |
| 50 Pa flow rate 0 m3/h maximum pressure |
| Surrounding environment must be relatively cleanOutside temperature must be 5 deg C lower than inside temperatureOverfrequent filter replacement should be avoidedFilter must be cleaned and replaced regularlyFlow rates depends on the work point, see ProClima software condition of use |