Schneider Electric ClimaSys CV Square D™ NSYCVF560M230PF Self-Extinguishing Forced Ventilation Fan, 230 VAC, 0.37/0.52 A, 68/85 W Power Rating, 560 cu-m/hr Air Flow, IP54 Enclosure

Square D™
Schneider Electric ClimaSys CV Square D™ NSYCVF560M230PF Self-Extinguishing Forced Ventilation Fan, 230 VAC, 0.37/0.52 A, 68/85 W Power Rating, 560 cu-m/hr Air Flow, IP54 Enclosure
SKU1485324
MFGR #NSYCVF560M230PF
Call For Price
List: Schneider Electric ClimaSys CV Square D™ Forced Ventilation Fan, Self-Extinguishing, 230 VAC, 0.37/0.52 A, 68/85 W Power, 59 dB Sound Level, 560 cu-m/hr Air Flow, Axial Motor, Injected Thermoplastic (ASA PC) Grille, IP54 Enclosure, 13.23 in H x 12.44 in W x 6.34 in D Dimensions
Schneider Electric ClimaSys CV Square D™ Forced Ventilation Fan, Self-Extinguishing, 230 VAC, 0.37/0.52 A, 68/85 W Power, 59 dB Sound Level, 560 cu-m/hr Air Flow, Axial Motor, Injected Thermoplastic (ASA PC) Grille, IP54 Enclosure, 13.23 in H x 12.44 in W x 6.34 in D Dimensions
Alternate Catalog Number NSYCVF560M230PF Application FORCED VENTILATION 560 M¦/H ARRA Compliant N Buy American Compliant N Catalog Number NSYCVF560M230PF Color OUTLET GRILLE GREY RAL 7035) Consist Of 1 axial motor;2 protective grille on the front and rear surfaces;1 filter front of axial motor;1 outlet grille front;1 cut-out template Country of Origin FR Currency USD Depth External : 161 mm EU RoHS Indicator Y Gross Volume Per Pack 1574.85 Gross Volume per Pack Metric 25807.07 Gross Volume UOM CI Gross Volume UOM Metric cm3 Gross Weight Per Pack 0.0355 lb Gross Weight per Pack Metric 3.55 Gross Weight UOM Metric kg Harmonization Tariff Schedule Code 8414596590 Height 23.0000 in Height [Metric] 23.0000 cm Item Group 80036 Length 34.0000 in Length [Metric] 34.0000 cm Material Outlet grille injected thermoplastic (ASA PC) Material Composition Declaration https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=export&pid=10178375&lang=en-us Returnable N Size EXTERNAL 161 MM,EXTERNAL 316 MM,EXTERNAL 336 MM Standard IP54 Sub Brand CLIMASYS CV Type Fan UNSPSC 39121321 Warranty Description Contractual Warranty:18 months Width 32.0000 in Width [Metric] 32.0000 cm Stock Status NONSTOCK Brand Square D™ Manufacturer Schneider Electric FORCED VENTILATION 560 M¦/H FREE FLOW RATE WITH STANDARD FILTER 562 M3/H 50 HZ-FREE FLOW RATE WITH STANDARD FILTER 586 M3/H 60 HZ,TERMINAL BLOCK The ClimaSys CV is recommended for installations in which the ambient temperature is lower than the desired temperature inside the enclosure The fans comprise an axial motor, a protective housing on the front and rear surfaces and a filter designed to retain dust particles Filter can be replaced during operation without risk of contact with the rotating element The outside temperature must be 5 deg C lower than the desired temperature inside the enclosure The filters that equipped the fans must be cleaned and replaced regularly The surrounding environment must be relatively clean and over frequent filter replacement should be avoided Bear in mind the pressure losses caused by the outlet element (grille with filter, ventilation louvre or simple opening) when determining the fan flow rate -40 to 70 deg C storage The cutout template supplied with the device avoids the need for marking and protects the surface of the enclosure during handling 68 W at 50 Hz, 85 W at 60 Hz power rating 68 W at 50 Hz, 85 W at 60 Hz power rating 0.52 A at 50 Hz, 0.37 A at 60 Hz current rating
content loaded
content loaded
content loaded
content loaded
content loaded
- Attributes
- Documents & Resources
- Applications
- Features
- Substitute Products
| Alternate Catalog Number | NSYCVF560M230PF |
| Application | FORCED VENTILATION 560 M¦/H |
| ARRA Compliant | N |
| Buy American Compliant | N |
| Catalog Number | NSYCVF560M230PF |
| Color | OUTLET GRILLE GREY RAL 7035) |
| Consist Of | 1 axial motor;2 protective grille on the front and rear surfaces;1 filter front of axial motor;1 outlet grille front;1 cut-out template |
| Country of Origin | FR |
| Currency | USD |
| Depth | External : 161 mm |
| EU RoHS Indicator | Y |
| Gross Volume Per Pack | 1574.85 |
| Gross Volume per Pack Metric | 25807.07 |
| Gross Volume UOM | CI |
| Gross Volume UOM Metric | cm3 |
| Gross Weight Per Pack | 0.0355 lb |
| Gross Weight per Pack Metric | 3.55 |
| Gross Weight UOM Metric | kg |
| Harmonization Tariff Schedule Code | 8414596590 |
| Height | 23.0000 in |
| Height [Metric] | 23.0000 cm |
| Item Group | 80036 |
| Length | 34.0000 in |
| Length [Metric] | 34.0000 cm |
| Material | Outlet grille injected thermoplastic (ASA PC) |
| Material Composition Declaration | https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=export&pid=10178375&lang=en-us |
| Returnable | N |
| Size | EXTERNAL 161 MM,EXTERNAL 316 MM,EXTERNAL 336 MM |
| Standard | IP54 |
| Sub Brand | CLIMASYS CV |
| Type | Fan |
| UNSPSC | 39121321 |
| Warranty Description | Contractual Warranty:18 months |
| Width | 32.0000 in |
| Width [Metric] | 32.0000 cm |
| Stock Status | NONSTOCK |
| Brand | Square D™ |
| Manufacturer | Schneider Electric |
| FORCED VENTILATION 560 M¦/H |
| FREE FLOW RATE WITH STANDARD FILTER 562 M3/H 50 HZ-FREE FLOW RATE WITH STANDARD FILTER 586 M3/H 60 HZ,TERMINAL BLOCK |
| The ClimaSys CV is recommended for installations in which the ambient temperature is lower than the desired temperature inside the enclosure |
| The fans comprise an axial motor, a protective housing on the front and rear surfaces and a filter designed to retain dust particles |
| Filter can be replaced during operation without risk of contact with the rotating element |
| The outside temperature must be 5 deg C lower than the desired temperature inside the enclosure |
| The filters that equipped the fans must be cleaned and replaced regularly |
| The surrounding environment must be relatively clean and over frequent filter replacement should be avoided |
| Bear in mind the pressure losses caused by the outlet element (grille with filter, ventilation louvre or simple opening) when determining the fan flow rate |
| -40 to 70 deg C storage |
| The cutout template supplied with the device avoids the need for marking and protects the surface of the enclosure during handling |
| 68 W at 50 Hz, 85 W at 60 Hz power rating |
| 68 W at 50 Hz, 85 W at 60 Hz power rating |
| 0.52 A at 50 Hz, 0.37 A at 60 Hz current rating |