or to view stock quantity and your pricing.
Steiner serves territories in Northern Illinois, Northwest Indiana and Southern Wisconsin. Please for assistance if outside our sales territory.
Killark® FXCS-0B4-LO GREEN/RED PUSHBUTT
SKU960358
MFGR #FXCS-0B4-LO
Your Cost: $986.27/ea
FXCS SERIES - ALUMINUM MOMENTARY CONTACT DOUBLE PUSH BUTTON COVER WITHDEVICE - FACTORY SEALED - GREEN BUTTON WITH "START" NAMEPLATE - REDBUTTON WITH LOCKOUT AND "STOP" NAMEPLATE - 1NO/1NC CONTACT RATING
FXCS SERIES - ALUMINUM MOMENTARY CONTACT DOUBLE PUSH BUTTON COVER WITHDEVICE - FACTORY SEALED - GREEN BUTTON WITH "START" NAMEPLATE - REDBUTTON WITH LOCKOUT AND "STOP" NAMEPLATE - 1NO/1NC CONTACT RATING
Action Momentary Actuator Double Pushbutton w/ Lockout Application SEAL-X Series is used to prevent the igniting of external hazardous atmospheres by the enclosed arcing devices in such areas as: hazardous locations due to the presence of flammable gases or vapors, combustible dusts or easily ignitable fibers or flyings ARRA Compliant C Buy American Compliant C Catalog Number FXCS-0B4-LO Color Green-Red Contact Mode Momentary Country of Origin US Currency USD Dimensions 5.3125 in H x 3.6875 in W x 2.59 in D Environmental Conditions Hazardous locations EU RoHS Indicator C Finish Epoxy Powder Baked Gross Volume Per Pack 174.24 Gross Volume per Pack Metric 2855.22 Gross Volume UOM CI Gross Volume UOM Metric cm3 Gross Weight Per Pack 3.0000 lb Gross Weight per Pack Metric 1.36 Gross Weight UOM Metric kg Harmonization Tariff Schedule Code 8536509035 Height 4.38 in Height [Metric] 11.1252 cm Legend Start/Stop Length 6.63 in Length [Metric] 16.8402 cm Material Copper-Free Aluminum Number Of Poles 2 Returnable Y Series FXCS Size 6.63 in x 6 in x 4.38 in Standard UL, CSA Standards ARRA CompliantBuy American Act CompliantRoHS CompliantUL File No. E53360/E12379CSA File No. LR11714Class I Divisions 1 and 2 Groups C, D Class I Zones 1 and 2 Groups IIB, IIA Class II Divisions 1 and 2 Groups E, F, G Class III Sub Brand SEAL-X Switch Type Double Pushbutton w/ Lockout Type Aluminum Factory Sealed Cover With Two Push Buttons UNSPSC 39122211 UPC 11 78393601693 UPC 12 783936016931 Width 6.00 in Width [Metric] 15.2400 cm Stock Status NONSTOCK Brand Killark Manufacturer Hubbell Amperage Rating 10 A Contact Configuration 1-NO/1-NC NEMA Rating NEMA 3/7CD/9EFG Number of Operators 2 Voltage Rating 600 VAC SEAL-X Series is used to prevent the igniting of external hazardous atmospheres by the enclosed arcing devices in such areas as: hazardous locations due to the presence of flammable gases or vapors, combustible dusts or easily ignitable fibers or flyings Killark SEAL-X Series Factory Sealed Control Stations provide control solutions in hazardous location areas to supply; START/STOP Motor Functions, LED Pilot Light Indications and more. Utilized in Class 1 Division 1 & 2, Class 1 Zone 1 & 2 areas where Type 3, 7 & 9 protection ratings are required for indoor and outdoor use. UL Listed and CSA Certified. Elimination of external sealing requirements Lower installation cost NEMA 3 weatherproof Color coded wiring with more wiring space for easier field installation Stainless steel captive screws for cover assembly Ground boss for grounding in the splice box Device bodies and covers are cast copper-free aluminum alloy Operating shaft in both pushbuttons and selector switches are stainless steel Pushbutton, selector switches and pilot light bodies are copper-free aluminum 60 A at 120 VAC, 30 A at 240 VAC, 15 A at 480 VAC, 12 A at 600 VAC inrush, 6 A at 120 VAC, 3 A at 240 VAC, 1.5 A at 480 VAC, 1.2 A at 600 VAC breaking, 10 A at 120 VAC, 10 A at 240 VAC, 10 A at 480 VAC carrying contact rating Pushbutton lockout must be factory installed 0.55 A at 125 VDC, 0.275 A at 250 VDC inrush, 0.55 A at 125 VDC, 0.275 A at 250 VDC breaking, 2.5 A at 125/250 VDC carrying
content loaded
content loaded
content loaded
content loaded
content loaded
- Attributes
- Documents & Resources
- Applications
- Features
- Substitute Products
| Action | Momentary |
| Actuator | Double Pushbutton w/ Lockout |
| Application | SEAL-X Series is used to prevent the igniting of external hazardous atmospheres by the enclosed arcing devices in such areas as: hazardous locations due to the presence of flammable gases or vapors, combustible dusts or easily ignitable fibers or flyings |
| ARRA Compliant | C |
| Buy American Compliant | C |
| Catalog Number | FXCS-0B4-LO |
| Color | Green-Red |
| Contact Mode | Momentary |
| Country of Origin | US |
| Currency | USD |
| Dimensions | 5.3125 in H x 3.6875 in W x 2.59 in D |
| Environmental Conditions | Hazardous locations |
| EU RoHS Indicator | C |
| Finish | Epoxy Powder Baked |
| Gross Volume Per Pack | 174.24 |
| Gross Volume per Pack Metric | 2855.22 |
| Gross Volume UOM | CI |
| Gross Volume UOM Metric | cm3 |
| Gross Weight Per Pack | 3.0000 lb |
| Gross Weight per Pack Metric | 1.36 |
| Gross Weight UOM Metric | kg |
| Harmonization Tariff Schedule Code | 8536509035 |
| Height | 4.38 in |
| Height [Metric] | 11.1252 cm |
| Legend | Start/Stop |
| Length | 6.63 in |
| Length [Metric] | 16.8402 cm |
| Material | Copper-Free Aluminum |
| Number Of Poles | 2 |
| Returnable | Y |
| Series | FXCS |
| Size | 6.63 in x 6 in x 4.38 in |
| Standard | UL, CSA |
| Standards | ARRA CompliantBuy American Act CompliantRoHS CompliantUL File No. E53360/E12379CSA File No. LR11714Class I Divisions 1 and 2 Groups C, D Class I Zones 1 and 2 Groups IIB, IIA Class II Divisions 1 and 2 Groups E, F, G Class III |
| Sub Brand | SEAL-X |
| Switch Type | Double Pushbutton w/ Lockout |
| Type | Aluminum Factory Sealed Cover With Two Push Buttons |
| UNSPSC | 39122211 |
| UPC 11 | 78393601693 |
| UPC 12 | 783936016931 |
| Width | 6.00 in |
| Width [Metric] | 15.2400 cm |
| Stock Status | NONSTOCK |
| Brand | Killark |
| Manufacturer | Hubbell |
| Amperage Rating | 10 A |
| Contact Configuration | 1-NO/1-NC |
| NEMA Rating | NEMA 3/7CD/9EFG |
| Number of Operators | 2 |
| Voltage Rating | 600 VAC |
| SEAL-X Series is used to prevent the igniting of external hazardous atmospheres by the enclosed arcing devices in such areas as: hazardous locations due to the presence of flammable gases or vapors, combustible dusts or easily ignitable fibers or flyings |
| Killark SEAL-X Series Factory Sealed Control Stations provide control solutions in hazardous location areas to supply; START/STOP Motor Functions, LED Pilot Light Indications and more. Utilized in Class 1 Division 1 & 2, Class 1 Zone 1 & 2 areas where Type 3, 7 & 9 protection ratings are required for indoor and outdoor use. UL Listed and CSA Certified. |
| Elimination of external sealing requirements |
| Lower installation cost |
| NEMA 3 weatherproof |
| Color coded wiring with more wiring space for easier field installation |
| Stainless steel captive screws for cover assembly |
| Ground boss for grounding in the splice box |
| Device bodies and covers are cast copper-free aluminum alloy |
| Operating shaft in both pushbuttons and selector switches are stainless steel |
| Pushbutton, selector switches and pilot light bodies are copper-free aluminum |
| 60 A at 120 VAC, 30 A at 240 VAC, 15 A at 480 VAC, 12 A at 600 VAC inrush, 6 A at 120 VAC, 3 A at 240 VAC, 1.5 A at 480 VAC, 1.2 A at 600 VAC breaking, 10 A at 120 VAC, 10 A at 240 VAC, 10 A at 480 VAC carrying contact rating |
| Pushbutton lockout must be factory installed |
| 0.55 A at 125 VDC, 0.275 A at 250 VDC inrush, 0.55 A at 125 VDC, 0.275 A at 250 VDC breaking, 2.5 A at 125/250 VDC carrying |